Copper Backflow Preventer

Backflow preventer is mainly used to prevent the medium in the pipeline from backflow due to pressure inversion, applicable to water, air and non-corrosive liquids, widely used in municipal water supply, building water supply and drainage, fire-fighting and industrial circulation system. Working temperature is generally 0 ℃ to 80 ℃, special materials can withstand higher temperatures. It is suitable for normal pressure to low and medium pressure working conditions. The main function is to realize double protection through the internal non-return and pressure relief structure to prevent backflow of contaminated media. Commonly used materials include copper alloy, stainless steel and ductile iron, compact structure, easy maintenance, to protect the system water quality safety and operational stability.
Copper Backflow Preventer

Copper Backflow Preventer

Model: DH11X / HS11X
Subtitle:Double check valve
The Copper Double Check Valve is a high performance compact unit designed to protect potable water systems from backflow contamination. Constructed of a durable lead-free copper alloy, it is ideal for residential, commercial and light industrial applications where water safety and reliability are critical.
Classification:backflow preventer

Product Overview

The Copper Double Check Valve is a high performance compact unit designed to protect potable water systems from backflow contamination. It is made of a durable lead-free copper alloy and is ideal for residential, commercial and light industrial applications where water safety and reliability are important.

Equipped with a double check valve assembly, this backflow preventer ensures effective backflow prevention even in low-risk applications. Its corrosion-resistant copper construction makes it suitable for potable water systems, and its compact design makes it easy to install in tight spaces.

Working Principle

The double check valve works through two separate check valves:

The first check valve: when the downstream pressure exceeds the water supply pressure, the check valve is closed to prevent backflow.

Second check valve: acts as a secondary barrier to provide additional protection in the event of a failure of the first check valve.

Shut-off valve: Integrated isolation valve for easy testing and maintenance without interrupting the water supply.

Main features

Lead-free copper construction: meets NSF/ANSI 372 standards and Safe Drinking Water Act (SDWA) requirements. Corrosion-resistant to ensure long-term durability of drinking water systems.

Dual check valve design: two independently operated check valves provide redundant backflow protection. Test plug facilitates field testing and maintenance.

COMPACT AND LIGHTWEIGHT: Space-saving design, ideal for residential and commercial installations. Easy to install horizontally or vertically. LOW PRESSURE DROP: Optimized flow path minimizes pressure loss and ensures efficient water supply.

Compliance and Certification: Meets ASSE 1015, CSA B64.6 and NSF/ANSI 372 standards for backflow prevention devices.

Product Advantages

Reliable protection: double check valves ensure fail-safe and prevent backflow.

Easy to maintain: Test plugs can be quickly tested in the field without disassembly.

Corrosion resistance: Copper construction ensures a long life for the drinking water system.

Cost-effective: Lower installation and maintenance costs compared to RPZ units.

Why Choose Us

Compliance: Meets all major backflow prevention industry standards.

DURABILITY: Lead-free copper construction resists corrosion and extends service life.

Versatility: suitable for residential, commercial and light industrial applications.

Support: comprehensive technical documentation and global service.

summarize

The Copper Double Check Valve is a reliable and cost-effective solution for protecting potable water systems from backflow contamination. Its lead-free copper construction, double check valve design and compact profile make it ideal for residential, commercial and irrigation applications. Complying with ASSE 1015, CSA B64.6, and NSF/ANSI 372 standards, the device ensures water supply safety and system reliability, providing peace of mind for engineers, contractors, and end users.

Product Parameters

Nominal diameter½" to 2" (DN15 to DN50)
Nominal pressurePN6-PN16, maximum working pressure 150 psi (10.3 bar)
Applicable temperature0.5°C-80°C
Valve MaterialLead-free copper alloy (C84400 or equivalent)
sealing materialEPDM or NBR (FDA drinking water compliant)
connection methodThreaded (NPT) or flanged (optional)

Copper Backflow Preventer Similar Products

The following are similar products. You can search for other related products.

Copper Backflow Preventer
The Copper Double Check Valve is a high performance compact unit designed to protect potable water systems from back...
Low resistance backflow preventer
The Low Resistance Backflow Preventer is a highly efficient device designed to prevent backflow and protect the water system from...
One-piece backflow preventer
The Integrated Backflow Preventer is a compact, high-performance device designed to prevent backflow and protect the supply...
Stainless steel threaded low resistance backflow preventer
The Stainless Steel Threaded Low Resistance Backflow Preventer is a compact and efficient device designed to prevent backflow...
Stainless steel low resistance backflow preventer
The stainless steel low pressure check valve is designed to prevent backflow and ensure unidirectional flow in low pressure systems. It adopts...
Threaded low resistance backflow preventer
The threaded low resistance backflow preventer is a highly efficient device designed to protect potable water systems from...
Stainless steel backflow preventer
The Stainless Steel Backflow Preventer is a high performance valve designed to protect your water system from water...
Copper Threaded Backflow Preventer
Copper threaded backflow preventer is a device used to prevent backflow of water and protect the safety of piping system...
Double check backflow preventer
Double check backflow preventer is an efficient device to prevent fluid backflow, widely used in drinking...